

The Reflow Spex shapes to your preferred angle for improved and predictable vascular access.
View a video demonstration of the Spex
This informative video provides a brief look at the remarkable capabilities of the speX Shapeable Support Catheter.
- Compatible with the physician’s preferred guide wire and procedural technique.
- Combine with the Reflow Wingman™ Crossing Catheter to optimize support.
- Use the Spex 35 Support Catheter with the Reflow SpexLP™

ACCESS FROM ANGLES
- Promotes improved and predictable access to the vasculature.
- Designed to fill a specific need based on clinical feedback.
- Allows the physician to straighten or reshape the angle as needed.
- Helps the physician perform procedures more effectively.
- Increases lubricity with a seamless, low-profile hydrophilic coating.
- Optimizes pushability and access through lesions
“The Spex Catheter makes it very easy to cross occlusions.”
– Jay Mathews, MD, MS, FACC
– Jay Mathews, MD, MS, FACC
- Stiff tip pierces through occlusions with guidewire
- Direct the tip into the micro channels as needed

CUSTOMIZABLE TIP MAINTAINS THE DESIRED ANGLE
Allows the physician to shape to the preferred angle and holds it throughout the procedure

COMPATIBLE WITH YOUR PREFERRED GUIDEWIRE & PROCEDURAL TECHNIQUE
Works with the Reflow Wingman™ Catheter for added support in lesion crossing


35
Model Number – Effective Length
SPN35050CE
SPN35050CE-5P*
SPN35090CE
SPN35090CE-5P*
SPN35135CE
SPN35135CE-5P*
SPN35150CE
SPN35150CE-5P*
Effective Length (cm)
50,90,135,150
Guidewire Compatability (in)
0.035
Max Outer Diameter (in/F)
0.06/4.6
Max Pressure (psi/kpa)
300/2068
Shapeable Tip Zone (in/mm)
.75/19
Sheath Compatibility (F/mm)
5/1.7
Hydrophilic Coating (cm)
40
*(-5P) Indicates 5 pack availability
©2024 Reflow Medical, Inc. All rights reserved. Reflow Medical, Spex and The Pulse of Medical Ingenuity are registered trademarks or trademarks of Reflow Medical, Inc. This device is restricted to use by or on the order of a physician. Refer to the Instructions for Use for a complete listing of the Indications, Contraindications, Warnings, Precautions, Adverse Events, and Procedural Steps
Indications, Safety, & Warnings
CAUTION: This device is restricted to use by or on the order of a physician. Refer to the Instructions for Use for a complete listing of the Indications, Contraindications, Warnings, Precautions, Adverse Events, and Procedural Steps.
Intended Use
The Spex Shapeable Support Microcatheter is intended to treat peripheral artery disease (PAD).
Indications for Use
The Spex Shapeable Support Microcatheter is intended to treat peripheral artery disease (PAD).
Contraindications
The Spex™ Shapeable Support Microcatheter is intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature. To facilitate access in conjunction with a guidewire, it may be desired to shape the tip of the microcatheter. They may be used to facilitate placement and exchange of guidewires and other interventional devices and provide a conduit for delivery of saline solutions or diagnostic/ therapeutic agents.
Warnings
• Single Use only. Do not reuse/resterilize. Reusing the device could result in compromised device performance, cross-infection and other safety related hazards including patient injury.
• Do not use if device is open or packaging is damaged.
• Never advance, withdraw or rotate an intravascular device against resistance until the cause is determined by fluoroscopy
• If the catheter is damaged, this product may cut into a blood vessel wall. Extreme caution needs to be taken when removing a damaged device. In the case of complications resulting from the removal of the entire system, stop immediately the procedure, and perform appropriate treatment at the discretion of the physician.
Precautions
• Store in a cool, dry, dark place. Storage of the device in extreme conditions may damage the device and/or affect device performance that could lead to patient injury.
• Use only appropriately sized ancillary device, as shown in the Specifications above.
• Maximum Injection Pressure: 360 psi (2482kpa).
• Use the catheter prior to the “Use By” date specified on the package.
• The catheter should only be used by physicians qualified to perform percutaneous vascular interventions.
• Precautions to prevent or reduce clotting should be taken when any catheter is used in the vascular system.
• Use of systemic heparinization and heparinized saline solution should be considered.
• Exercise care while handling the microcatheter during procedure to reduce the possibly of accidental damage, kinking or bending.
• Manipulation of the microcatheter should only occur under fluoroscopy.
©2024 Reflow Medical, Inc. All rights reserved. Reflow Medical, Spex and The Pulse of Medical Ingenuity are registered trademarks or trademarks of Reflow Medical, Inc. This device is restricted to use by or on the order of a physician. Refer to the Instructions for Use for a complete listing of the Indications, Contraindications, Warnings, Precautions, Adverse Events, and Procedural Steps.

QUESTIONS?
TALK TO A REFLOW PRO.
For more information, please send us your question or request today.
A Reflow pro will get back to you.
